HUYNDAI Air Receiver Tank-2000L
৳ 180,000.00৳ 190,000.00 (-5%)
Key Specifications:
- Model: 2/1.0
- Volume: 2 m³ (2000 liters)
- Maximum Working Pressure: 1.0 MPa (10 bar / 145 psi)
- Design Pressure: 1.1 MPa
- Test Pressure: 1.38 MPa
- Material: Q345R (pressure vessel carbon steel)
- Manufacture Date: December 2025
- Vessel Class: Class I (Class 1 pressure vessel)
Safety Warnings:
- Over pressure Protection: If the actual air intake volume of the compressor exceeds the discharge capacity of this tank's safety valve, you must install an additional safety valve on the system pipeline (refer to the completed construction drawings for technical specifications).
- Air Quality Control: When using a reciprocating air compressor or any other compressor that produces high oil content, the compressed air must pass through an oil and water removal treatment system before it is allowed to enter the tank.
- Operating Limits: The tank must strictly be operated within the design limits for working pressure and working temperature specified on the nameplate.
- Medium Restrictions: The working medium inside the tank must strictly comply with the regulations outlined in the final construction drawings and the nameplate specifications (compressed air).
- User Manual: Users must read the gas storage tank user manual carefully before installation and operation.
Key Specifications:
- Model: 2/1.0
- Volume: 2 m³ (2000 liters)
- Maximum Working Pressure: 1.0 MPa (10 bar / 145 psi)
- Design Pressure: 1.1 MPa
- Test Pressure: 1.38 MPa
- Material: Q345R (pressure vessel carbon steel)
- Manufacture Date: December 2025
- Vessel Class: Class I (Class 1 pressure vessel)
Safety Warnings:
- Over pressure Protection: If the actual air intake volume of the compressor exceeds the discharge capacity of this tank’s safety valve, you must install an additional safety valve on the system pipeline (refer to the completed construction drawings for technical specifications).
- Air Quality Control: When using a reciprocating air compressor or any other compressor that produces high oil content, the compressed air must pass through an oil and water removal treatment system before it is allowed to enter the tank.
- Operating Limits: The tank must strictly be operated within the design limits for working pressure and working temperature specified on the nameplate.
- Medium Restrictions: The working medium inside the tank must strictly comply with the regulations outlined in the final construction drawings and the nameplate specifications (compressed air).
- User Manual: Users must read the gas storage tank user manual carefully before installation and operation.




Reviews